DXC Series Integral AC Fan Air Cooler
The cooler, through vacuum brazing process, is driving by all-in-one axial flow fan which can run for a long time to achieve stable cooling effect.
1. Temperature controller can be installed.
2. A variety of pressure protection forms can be selected.
3. The oil inlet and outlet of the cooler are standard G thread, also can be customized or connected with SAE flange as required.
The outer fins are sufficient; the outer fin adopts a corrugated structure to ensure sufficient heat dissipation area and withstand voltage value.
Equipped with high-quality brand high-power and high-efficiency motors; it can be suitable for high-efficiency and long-term operation in various complex occasions.
High-quality dynamic balance correction fan blades, can run stably for a long time without deformation and durable.
The shaft sleeve is made of high-strength and high-density die-cast aluminum alloy material to prevent bursting under high-speed operation.
The aluminum radiator runner grooves of the DX series products are all made of thickened pressure-resistant B profiles. The real material is the bottom line of our industry.
Quality Assurance, Easy Installation, One Year Warranty
The cooler, through vacuum brazing process, is driving by high-efficiency standard motor and high-strength fan blades to achieve stable cooling effect.
· Three-phase asynchronous motor: large rotation, good stability, continuous work for 24 hours.
· Thickened Aluminum,Vacuum Brazing Technology.
· Fast Heat Dissipation.
· Strong Winds.
· Safety at Work.
· Environmentally Friendly and Energy-saving.
· Low Noise.
· Thickened casing, spraying treatment, fine workmanship, not easy to rust.
· Temperature controller can be installed.
· A variety of pressure protection forms can be selected.
· The oil inlet and outlet of the cooler are standard G thread, also can be customized or connected with SAE flange as required.
Quality Assurance, Easy Installation, One Year Warranty
Don't corrode aluminum alloys:
① Hydraulic oil
② lubricating oil
③ Water and water-soluble liquids...
Water and Glycol Mixtures, please consult us.
Model | DXC-2 | DXC-3 | DXC-4 | DXC-5 | DXC-6 | DXC-7 | DXC-8 | DXC-9 | DXC-10 | DXC-11 |
Cooling Capacity* (kW) |
10 | 15 | 20 | 25 | 30 | 40 | 50 | 60 | 70 | 80 |
Rated Flow (L/min) |
80 | 100 | 150 | 200 | 250 | 300 | 350 | 400 | 500 | 600 |
Max.Working Pressure (bar) |
20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 |
Fan Power (W) |
50/55 | 129/129 | 180/180 | 180/180 | 250/250 | 250/250 | 700/780 | 750/800 | 4*129 | 4*180 |
Working Voltage (V) | 220/380 | 220/380 | 220/380 | 220/380 | 220/380 | 220/380 | 220/380 | 220/380 | 220/380 | 220/380 |
Inlet&Outlet Thread | G¾" | G1" | G1¼" | G1¼" | G1¼" | G1¼" | G1½" | G1½" | G1½" | G1½" |
Thermometric Thread | G3/8" | G3/8" | G3/8" | G3/8" | G3/8" | G3/8" | G3/8" | G3/8" | G3/8" | G3/8" |
Noise Level** (dB) | 58 | 62 | 71 | 72 | 74 | 76 | 80 | 83 | 86 | 89 |
A (mm±5) |
365 | 425 | 530 | 585 | 630 | 630 | 750 | 835 | 970 | 1080 |
B (mm±5) |
400 | 500 | 565 | 600 | 625 | 625 | 765 | 920 | 1060 | 1205 |
C (mm±2) |
250 | 250 | 260 | 300 | 300 | 330 | 400 | 400 | 400 | 400 |
D (mm±2) |
230 | 290 | 390 | 450 | 490 | 490 | 560 | 645 | 700 | 700 |
E (mm±2) |
210 | 210 | 220 | 260 | 260 | 280 | 350 | 350 | 350 | 350 |
F (mm±5) |
295 | 384 | 434 | 475 | 495 | 495 | 634 | 780 | 920 | 1070 |
G (mm±5) |
45 | 50 | 55 | 55 | 55 | 55 | 55 | 60 | 60 | 60 |
K (mm±10) |
240 | 280 | 310 | 330 | 330 | 350 | 390 | 465 | 380 | 400 |
L (mm±2) |
40 | 40 | 40 | 40 | 45 | 45 | 45 | 50 | 50 | 50 |
M (mm±2) |
12*18 | 12*18 | 12*18 | 12*18 | 14*22 | 14*22 | 14*22 | 14*22 | 14*22 | 14*22 |
W1 | 180 | 200 | 250 | 300 | 300 | 300 | 350 | 400 | 450 | 500 |
W2 | 360 | 400 | 500 | 600 | 600 | 700 | 800 | 900 | 1000 | 650 |
Note: * Cooling capacity: cooling power at △T=40℃. ** The noise value is measured at a distance of 1m from the cooler, which is only for reference. Because it is affected by the surrounding environment, medium viscosity and reflection. *** This table only takes AC380V-50HZ as an example. **** Motor power protection level: IP44; Insulation class: F; CE standard. (Other options please contact DONGXU) |


Hydraulic system circuit, independent cooling circuit and lubricating oil cooling system.
For examples, machine tools, mining machinery, hydraulic machinery, power station, wind power equipment, and so on.

Machine tools

Hydraulic Machinery

Lubrication systems

Power Station
DXC | 8 | A3 | 5 | N | C | X | O | O |
Cooler Type: Integral AC fan Series |
Plate Size: 2/3/4/5/6/7/8/9/10/11 |
Voltage: A2=AC220V A3=AC380V |
Frequency: 5=50Hz⬅Standard 6=60Hz |
Bypass Valve: N=Build-in⬅Standard W=External M=Without Bypass Valve |
Oil Hole Direction: C=Side in side out⬅Standard S=Up in up out |
Wind Direction: X=Suction⬅Standard C=Blowing |
Temp. Controller: O=Without controller⬅Standard T=Temp. Switches--Action Temp.: T50=50℃,T60=60℃,T70=70℃ C=Temp. Transmitter-- C1=Compact,C2=Digital |
Heatsink Protection: O=Without protection⬅Standard S=Anti-Stone net C=Dust net |