DXD Series DC Condensing Fan Air Cooler
Jaminan Kualitas, Instalasi Gampang, Garansi Setaun
Liwat proses brazing vakum, adhem didorong dening penggemar aksial terpadu, sing bisa mlaku suwe lan entuk efek pendinginan sing stabil.
· Pengontrol suhu bisa diinstal.
· Ana macem-macem bentuk proteksi tekanan.
· Inlet lan stopkontak lenga saka cooler minangka benang G standar, lan flang SAE uga bisa disesuaikan utawa disambungake miturut syarat.
Model | DXD-2 | DXD-3 | DXD-4 | DXD-5 | DXD-6 | DXD-7 | DXD-8 | DXD-9 | DXD-10 |
Kapasitas pendinginan * (kW) | 8 | 13 | 18 | 22 | 30 | 40 | 45 | 55 | 65 |
Alur Rated (L/min) | 80 | 100 | 150 | 200 | 250 | 300 | 350 | 400 | 500 |
Max. Tekanan Kerja (bar) | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 |
Daya Fan (W) | 150 | 200 | 200 | 2*150 | 2*150 | 2*150 | 2*200 | 4*200 | 4*200 |
Tegangan kerja (V) | 24 | 24 | 24 | 24 | 24 | 24 | 24 | 24 | 24 |
Utas Inlet & Outlet | G1¾'' | G1" | G1¼'' | G1¼'' | G1¼'' | G1¼'' | G1½'' | G1½'' | G1½'' |
Thread Termometrik | G3/8" | G3/8" | G3/8" | G3/8" | G3/8" | G3/8" | G3/8" | G3/8" | G3/8" |
Tingkat Kebisingan**(dB) | 52 | 68 | 71 | 72 | 74 | 75 | 78 | 79 | 84 |
A (mm±5) | 365 | 425 | 530 | 585 | 630 | 630 | 750 | 835 | 970 |
B (mm±5) | 400 | 500 | 565 | 600 | 625 | 625 | 765 | 920 | 1060 |
C (mm±2) | 250 | 250 | 260 | 300 | 300 | 330 | 400 | 400 | 400 |
D (mm±2) | 230 | 290 | 390 | 450 | 490 | 490 | 560 | 645 | 700 |
E (mm±2) | 210 | 210 | 220 | 260 | 260 | 280 | 350 | 350 | 350 |
F (mm±5) | 295 | 384 | 434 | 475 | 495 | 495 | 634 | 780 | 920 |
G (mm±5) | 45 | 50 | 55 | 55 | 55 | 55 | 55 | 60 | 60 |
K (mm±10) | 240 | 280 | 310 | 330 | 330 | 350 | 390 | 465 | 380 |
L (mm±2) | 40 | 40 | 40 | 40 | 45 | 45 | 45 | 50 | 50 |
M (mm±2) | 12*18 | 12*18 | 12*18 | 12*18 | 14*22 | 14*22 | 14*22 | 14*22 | 14*22 |
W1 | 180 | 200 | 250 | 300 | 300 | 300 | 350 | 400 | 450 |
W2 | 360 | 400 | 500 | 600 | 600 | 700 | 800 | 900 | 1000 |
Cathetan: * Kapasitas pendinginan: daya pendinginan ing △T=40 ℃. ** Nilai swara diukur ing jarak 1m saka cooler, sing mung kanggo referensi. Amarga kena pengaruh lingkungan sekitar, viskositas medium lan refleksi. *** Tabel iki mung njupuk AC380V-50HZ minangka conto. **** Tingkat proteksi daya motor: IP44;Kelas isolasi: F;standar CE. (Pilihan liyane hubungi DONGXU) |
Sirkuit sistem hidrolik, sirkuit pendingin independen lan sistem pendinginan minyak pelumas.
Contone, mesin mlaku, mesin alat mesin, mesin pertanian, kendaraan teknik, mesin konstruksi, lan liya-liyane.
Mesin mlaku
Piranti mesin
tetanèn
Teknik
Konstruksi
DXD | 8 | A2 | N | C | X | O | O |
Tipe Cooler: Integral DC Condenser Fan Series | Ukuran piring: 2/3/4/5/6/7/8/9/10 | Tegangan: A2 = DC24V⬅Standar A1 = DC12V | Katup Bypass: N = Build-in⬅Standar W = Eksternal M = Tanpa Katup Bypass | Arah Lubang Minyak: C = Sisih ing sisih metu⬅Standar S = munggah ing munggah metu | Arah Angin: X = Nyedhot⬅Standar C = nggegirisi | Temp.pengontrol: O=Tanpa pengontrol⬅Standar Z = Saklar kontrol suhu sing dilindhungi dhewe sing terintegrasi C = SuhuPemancar-- C1 = Kompak, C2 = Digital | Perlindungan Heatsink: O=Tanpa proteksi⬅Standar S = Anti-Batu net C = jaring bledug |
1. Ngadhemke kudu diselehake ing panggonan uga-ventilated, lan iku gampang kanggo menehi hasil karo rereget ing sisih welingan online.Ana kudu spasi (ing ndhuwur radius agul-agul angin) sadurunge lan sawise kanggo nggampangake sirkulasi udara lan efek exchange panas apik.
2. Kanggo nglindhungi cooler saka pecah, nalika cooler wis diinstal ing sirkuit bali lenga, sirkuit unloading bypass kudu diinstal ing podo karo cooler, lan nalika relief meksa ketemu gelombang cembung, bisa dibukak lan unloaded preferentially.
3. Kanggo instalasi sing bener, disaranake nggunakake selang, nginstal sirkuit unloading bypass kanthi bener, utawa nggunakake metode pendinginan sirkulasi independen.
4. Kanggo ngresiki sisih udhara, udhara kompres utawa banyu panas bisa digunakake kanggo nyopot ing arah lembaran aluminium.Mangga mbayar manungsa waé kanggo daya mati nalika reresik, lan nglindhungi coil penggemar saka ngetik banyu.