Penyejuk Udara Berkesan Berbilang Fungsi Siri DXT
Penyejuk, melalui proses pematerian vakum, adalah tekanan yang stabil,yang boleh dilengkapi dengan pelbagai jenis motor dan digunakan secara meluas dalam banyak bidang.
· Pengawal suhu boleh dipilih.
· Pelbagai bentuk perlindungan tekanan boleh dipilih.
Penyejuk Udara Didorong Motor Berkecekapan Tinggi Siri DXT
Model | A | B | C | D | E | G | H | K | L | M | X | F | W1 | W2 |
DXT-2-A3 | 352 | 415 | 250 | 150 | 200 | 115 | 20 | 470 | 25 | Φ14 | G1" | 345 | 150 | 300 |
DXT-3-A3 | 456 | 540 | 300 | 200 | 250 | 160 | 20 | 500 | 25 | Φ14 | G1" | 460 | 200 | 400 |
DXT-4-A3 | 450 | 560 | 300 | 200 | 250 | 160 | 20 | 552 | 30 | Φ14 | G1¼" | 469 | 220 | 450 |
DXT-5-A3 | 470 | 710 | 300 | 200 | 250 | 165 | 20 | 559 | 30 | Φ14 | G1¼" | 620 | 220 | 450 |
DXT-6-A3 | 617 | 810 | 400 | 310 | 350 | 235 | 20 | 613 | 50 | Φ16 | G1¼" | 720 | 280 | 550 |
DXT-7-A3 | 617 | 960 | 400 | 310 | 350 | 235 | 20 | 660 | 50 | Φ16 | G1¼" | 870 | 280 | 550 |
DXT-8-A3 | 710 | 980 | 450 | 400 | 400 | 280 | 20 | 748 | 50 | Φ16 | G1½" | 880 | 500 | 1000 |
DXT-9-A3 | 990 | 1350 | 580 | 440 | 215 | 780 | 40 | 730 | 63 | Φ16 | Bebibir | 1182 | 550 | 1200 |
DXT-10-A3 | 990 | 1350 | 580 | 440 | 215 | 780 | 40 | 780 | 63 | Φ16 | Bebibir | 1172 | 620 | 1200 |
DXT-11-A3 | 1276 | 1570 | 750 | 525 | 210 | 1064 | 48 | 920 | 100 | Φ16 | Bebibir | 1332 | 800 | 1600 |
Penyejuk Udara Dipacu Motor Hidraulik Siri DXT
Model | A | B | C | D | E | G | H | L | M | X | F | W1 | W2 |
DXT-2-A5 | 352 | 415 | 250 | 150 | 200 | 115 | 20 | 25 | Φ14 | G1" | 345 | 150 | 300 |
DXT-3-A5 | 456 | 540 | 300 | 200 | 250 | 160 | 20 | 25 | Φ14 | G1¼" | 460 | 200 | 400 |
DXT-4-A5 | 450 | 560 | 300 | 200 | 250 | 160 | 20 | 30 | Φ14 | G1¼" | 469 | 220 | 450 |
DXT-5-A5 | 470 | 710 | 300 | 200 | 250 | 165 | 20 | 30 | Φ14 | G1¼" | 620 | 220 | 450 |
DXT-6-A5 | 617 | 810 | 400 | 310 | 350 | 235 | 20 | 50 | Φ16 | G1¼" | 720 | 280 | 550 |
DXT-7-A5 | 617 | 960 | 400 | 310 | 350 | 235 | 20 | 50 | Φ16 | G1¼" | 870 | 280 | 550 |
DXT-8-A5 | 710 | 980 | 450 | 400 | 400 | 280 | 20 | 50 | Φ16 | G1½" | 880 | 500 | 1000 |
DXT-9-A5 | 990 | 1350 | 580 | 440 | 215 | 780 | 40 | 63 | Φ16 | Bebibir | 1182 | 550 | 1200 |
DXT-10-A5 | 990 | 1350 | 580 | 440 | 215 | 780 | 40 | 63 | Φ16 | Bebibir | 1172 | 620 | 1200 |
DXT-11-A5 | 1276 | 1570 | 750 | 525 | 210 | 1064 | 48 | 100 | Φ16 | Bebibir | 1332 | 800 | 1600 |
DXT Series DC Condenser Fan Jenis Penyejuk Udara
Model | A | B | C | D | E | G | H | L | M | X | F | W1 | W2 |
DXT-1-A2 | 270 | 335 | 200 | 80 | 150 | 65 | 15 | 25 | Φ14 | G1" | 270 | 100 | 250 |
DXT-2-A2 | 352 | 415 | 250 | 150 | 200 | 115 | 20 | 25 | Φ14 | G1" | 345 | 150 | 300 |
DXT-3-A2 | 456 | 540 | 300 | 200 | 250 | 160 | 20 | 25 | Φ14 | G1" | 460 | 200 | 400 |
DXT-4-A2 | 450 | 560 | 300 | 200 | 250 | 160 | 20 | 30 | Φ14 | G1¼" | 469 | 220 | 450 |
DXT-5-A2 | 470 | 710 | 300 | 200 | 250 | 165 | 20 | 30 | Φ14 | G1¼" | 620 | 220 | 450 |
DXT-6-A2 | 617 | 810 | 400 | 310 | 350 | 235 | 20 | 50 | Φ16 | G1¼" | 720 | 280 | 550 |
Jadual parameter Komprehensif Siri DXT
Model | Voltan Motor (V) | Kuasa Motor (KW) | Kelajuan Bilah (r/min) | Tahap Kebisingan (dB) | Kapasiti Penyejukan (KW) | Max.Tekanan kerja (bar) | Max.Temp. (℃) | Aliran Maks (l/min) |
DXT-1 | 12 | 0.12 | 2700 | 70 | 5.5 | 20 | 130 | 60 |
24 | 0.15 | |||||||
DXT-2 | 12 | 0.12 | 2700 | 75 | 10 | 20 | 130 | 100 |
24 | 0.15 | 73 | ||||||
220/380 | 0.25 | 1450 | 78 | |||||
Motor Hidraulik 10ccm | / | 2800 | 77 | |||||
DXT-3 | 12 | 0.2 | 2700 | 76 | 16 | 20 | 130 | 150 |
24 | 0.2 | 78 | ||||||
220/380 | 0.37 | 1450 | 79 | |||||
Motor Hidraulik 10ccm | / | 2800 | 78 | |||||
DXT-4 | 12 | 0.2 | 2700 | 77 | 19 | 20 | 130 | 200 |
24 | 0.2 | 78 | ||||||
220/380 | 0.37 | 1450 | 79 | |||||
Motor Hidraulik 10ccm | / | 2800 | ||||||
DXT-5 | 12 | 0.2 | 2700 | 79 | 28 | 20 | 130 | 250 |
24 | 0.2 | |||||||
220/380 | 0.75 | 1450 | 82 | |||||
Motor Hidraulik 10ccm | / | 1500 | 80 | |||||
DXT-6 | 220/380 | 1.5 | 1450 | 87 | 35 | 20 | 130 | 300 |
Motor Hidraulik 16ccm | / | 1500 | 84 | |||||
DXT-7 | 220/380 | 1.5 | 1450 | 87 | 55 | 20 | 130 | 350 |
Motor Hidraulik 16ccm | / | 1500 | 84 | |||||
DXT-8 | 220/381 | 2.2 | 1450 | 89 | 70 | 20 | 130 | 400 |
Motor Hidraulik 16ccm | / | 1500 | 85 | |||||
DXT-9 | 220/381 | 4 | 1450 | 96 | 110 | 20 | 130 | 450 |
Motor Hidraulik 25ccm | / | 1500 | 87 | |||||
DXT-10 | 220/382 | 7.5 | 1450 | 102 | 140 | 20 | 130 | 500 |
Motor Hidraulik 25ccm | / | 1500 | 92 | |||||
DXT-11 | 220/382 | 11 | 1450 | 106 | 245 | 20 | 130 | 600 |
Motor Hidraulik 32ccm | / | 1500 | 97 |
Litar sistem hidraulik, litar penyejukan bebas dan sistem penyejukan minyak pelincir.
Contohnya, alat mesin, jentera perlombongan, jentera hidraulik, stesen janakuasa, peralatan kuasa angin, dan sebagainya.
Jentera pembinaan
Jentera kejuruteraan
Jentera hidraulik
Jentera perlombongan
Jentera berjalan kaki
DXT | 8 | A3 | M | X | O | O |
Jenis Penyejuk: Siri Berkesan Pelbagai fungsi | Saiz Plat: 1/2/3/4/5/6/7/8/9/10/11 | Cara memandu: A1=DC12V Kipas pemeluwapan A2=DC24V Kipas pemeluwapan A3=AC380V A4=AC440V Motor berkecekapan tinggi A5=Motor Hidraulik | Injap Pintasan: M=Tanpa Injap Pintasan⬅Standard W= Luaran | Arah angin: X=Sedutan⬅Standard C=Bertiup | Temp.Pengawal: O=Tanpa pengawal⬅Standard T=Suhu.Suis--Suhu Tindakan: T50=50℃,T60=60℃,T70=70℃ C=Suhu.Pemancar-- C1=Kompak,C2=Digital Z=Bersepadu dengan suis kawalan suhu pelindung.(Hanya tersedia apabila mod pemacu ialah kipas pemeluwapan) | Perlindungan Heatsink: O=Tanpa perlindungan⬅Standard S=Jaring Anti-Batu |
1. Diameter paip hendaklah dipadankan dengan saiz salur masuk dan keluar minyak.Ia boleh menjadi lebih kecil pada masa yang sama, tetapi tidak boleh menjadi lebih besar pada masa yang sama.Gunakan hos tekanan tinggi dan teruskan kepala sebanyak mungkin untuk mengurangkan rintangan balik minyak.
2. Apabila menggunakan kaedah penyejukan pemulangan minyak, litar pemunggahan pintasan mesti dipasang, dan tekanan pembukaan injap tekanan belakang adalah kurang daripada 0.5MPa untuk mengelakkan radiator daripada rosak akibat tekanan nadi yang berlebihan apabila sistem dimulakan.
3. Lokasi penyejuk udara harus mengelakkan getaran dan tebukan, dan pengambilan udara dan ekzos harus bebas dan tidak terhalang, dan pemasangan harus tegas.
4. Tidak digalakkan memasang penapis di saluran keluar minyak.