Ang cooler, sa pamamagitan ng vacuum brazing na proseso, ay stable pressure,na maaaring gamitan ng iba't ibang uri ng motor at malawakang magamit sa maraming larangan.
· Temperature controller ay maaaring mapili.
· Maaaring pumili ng iba't ibang uri ng proteksyon sa presyon.
DXT Series High Efficiency Motor Driven Air Cooler
Modelo | A | B | C | D | E | G | H | K | L | M | X | F | W1 | W2 |
DXT-2-A3 | 352 | 415 | 250 | 150 | 200 | 115 | 20 | 470 | 25 | Φ14 | G1" | 345 | 150 | 300 |
DXT-3-A3 | 456 | 540 | 300 | 200 | 250 | 160 | 20 | 500 | 25 | Φ14 | G1" | 460 | 200 | 400 |
DXT-4-A3 | 450 | 560 | 300 | 200 | 250 | 160 | 20 | 552 | 30 | Φ14 | G1¼" | 469 | 220 | 450 |
DXT-5-A3 | 470 | 710 | 300 | 200 | 250 | 165 | 20 | 559 | 30 | Φ14 | G1¼" | 620 | 220 | 450 |
DXT-6-A3 | 617 | 810 | 400 | 310 | 350 | 235 | 20 | 613 | 50 | Φ16 | G1¼" | 720 | 280 | 550 |
DXT-7-A3 | 617 | 960 | 400 | 310 | 350 | 235 | 20 | 660 | 50 | Φ16 | G1¼" | 870 | 280 | 550 |
DXT-8-A3 | 710 | 980 | 450 | 400 | 400 | 280 | 20 | 748 | 50 | Φ16 | G1½" | 880 | 500 | 1000 |
DXT-9-A3 | 990 | 1350 | 580 | 440 | 215 | 780 | 40 | 730 | 63 | Φ16 | Flange | 1182 | 550 | 1200 |
DXT-10-A3 | 990 | 1350 | 580 | 440 | 215 | 780 | 40 | 780 | 63 | Φ16 | Flange | 1172 | 620 | 1200 |
DXT-11-A3 | 1276 | 1570 | 750 | 525 | 210 | 1064 | 48 | 920 | 100 | Φ16 | Flange | 1332 | 800 | 1600 |
DXT Series Hydraulic Motor Driven Air Cooler
Modelo | A | B | C | D | E | G | H | L | M | X | F | W1 | W2 |
DXT-2-A5 | 352 | 415 | 250 | 150 | 200 | 115 | 20 | 25 | Φ14 | G1" | 345 | 150 | 300 |
DXT-3-A5 | 456 | 540 | 300 | 200 | 250 | 160 | 20 | 25 | Φ14 | G1¼" | 460 | 200 | 400 |
DXT-4-A5 | 450 | 560 | 300 | 200 | 250 | 160 | 20 | 30 | Φ14 | G1¼" | 469 | 220 | 450 |
DXT-5-A5 | 470 | 710 | 300 | 200 | 250 | 165 | 20 | 30 | Φ14 | G1¼" | 620 | 220 | 450 |
DXT-6-A5 | 617 | 810 | 400 | 310 | 350 | 235 | 20 | 50 | Φ16 | G1¼" | 720 | 280 | 550 |
DXT-7-A5 | 617 | 960 | 400 | 310 | 350 | 235 | 20 | 50 | Φ16 | G1¼" | 870 | 280 | 550 |
DXT-8-A5 | 710 | 980 | 450 | 400 | 400 | 280 | 20 | 50 | Φ16 | G1½" | 880 | 500 | 1000 |
DXT-9-A5 | 990 | 1350 | 580 | 440 | 215 | 780 | 40 | 63 | Φ16 | Flange | 1182 | 550 | 1200 |
DXT-10-A5 | 990 | 1350 | 580 | 440 | 215 | 780 | 40 | 63 | Φ16 | Flange | 1172 | 620 | 1200 |
DXT-11-A5 | 1276 | 1570 | 750 | 525 | 210 | 1064 | 48 | 100 | Φ16 | Flange | 1332 | 800 | 1600 |
DXT Series DC Condenser Fan Type Air Cooler
Modelo | A | B | C | D | E | G | H | L | M | X | F | W1 | W2 |
DXT-1-A2 | 270 | 335 | 200 | 80 | 150 | 65 | 15 | 25 | Φ14 | G1" | 270 | 100 | 250 |
DXT-2-A2 | 352 | 415 | 250 | 150 | 200 | 115 | 20 | 25 | Φ14 | G1" | 345 | 150 | 300 |
DXT-3-A2 | 456 | 540 | 300 | 200 | 250 | 160 | 20 | 25 | Φ14 | G1" | 460 | 200 | 400 |
DXT-4-A2 | 450 | 560 | 300 | 200 | 250 | 160 | 20 | 30 | Φ14 | G1¼" | 469 | 220 | 450 |
DXT-5-A2 | 470 | 710 | 300 | 200 | 250 | 165 | 20 | 30 | Φ14 | G1¼" | 620 | 220 | 450 |
DXT-6-A2 | 617 | 810 | 400 | 310 | 350 | 235 | 20 | 50 | Φ16 | G1¼" | 720 | 280 | 550 |
Talahanayan ng Comprehensive na parameter ng DXT Series
Modelo | Boltahe ng Motor (V) | Power motor (KW) | Bilis ng Blade (r/min) | Antas ng Ingay (dB) | Kapasidad ng Paglamig (KW) | Max. Presyon sa pagtatrabaho (bar) | Max.Temp. (℃) | Max.Flow (l/min) |
DXT-1 | 12 | 0.12 | 2700 | 70 | 5.5 | 20 | 130 | 60 |
24 | 0.15 | |||||||
DXT-2 | 12 | 0.12 | 2700 | 75 | 10 | 20 | 130 | 100 |
24 | 0.15 | 73 | ||||||
220/380 | 0.25 | 1450 | 78 | |||||
Hydraulic Motor 10ccm | / | 2800 | 77 | |||||
DXT-3 | 12 | 0.2 | 2700 | 76 | 16 | 20 | 130 | 150 |
24 | 0.2 | 78 | ||||||
220/380 | 0.37 | 1450 | 79 | |||||
Hydraulic Motor 10ccm | / | 2800 | 78 | |||||
DXT-4 | 12 | 0.2 | 2700 | 77 | 19 | 20 | 130 | 200 |
24 | 0.2 | 78 | ||||||
220/380 | 0.37 | 1450 | 79 | |||||
Hydraulic Motor 10ccm | / | 2800 | ||||||
DXT-5 | 12 | 0.2 | 2700 | 79 | 28 | 20 | 130 | 250 |
24 | 0.2 | |||||||
220/380 | 0.75 | 1450 | 82 | |||||
Hydraulic Motor 10ccm | / | 1500 | 80 | |||||
DXT-6 | 220/380 | 1.5 | 1450 | 87 | 35 | 20 | 130 | 300 |
Hydraulic Motor 16ccm | / | 1500 | 84 | |||||
DXT-7 | 220/380 | 1.5 | 1450 | 87 | 55 | 20 | 130 | 350 |
Hydraulic Motor 16ccm | / | 1500 | 84 | |||||
DXT-8 | 220/381 | 2.2 | 1450 | 89 | 70 | 20 | 130 | 400 |
Hydraulic Motor 16ccm | / | 1500 | 85 | |||||
DXT-9 | 220/381 | 4 | 1450 | 96 | 110 | 20 | 130 | 450 |
Hydraulic Motor 25ccm | / | 1500 | 87 | |||||
DXT-10 | 220/382 | 7.5 | 1450 | 102 | 140 | 20 | 130 | 500 |
Hydraulic Motor 25ccm | / | 1500 | 92 | |||||
DXT-11 | 220/382 | 11 | 1450 | 106 | 245 | 20 | 130 | 600 |
Hydraulic Motor 32ccm | / | 1500 | 97 |
Hydraulic system circuit, independent cooling circuit at lubricating oil cooling system.
Halimbawa, mga kagamitan sa makina, makinarya sa pagmimina, makinarya ng haydroliko, istasyon ng kuryente, kagamitan sa lakas ng hangin, at iba pa.
Makinarya sa konstruksyon
Makinarya sa engineering
Hydraulic na makinarya
Makinarya sa pagmimina
Makinarya sa paglalakad
DXT | 8 | A3 | M | X | O | O |
Uri ng Cooler: Multi-functional na Epektibong Serye | Laki ng Plate: 1/2/3/4/5/6/7/8/9/10/11 | Paraan sa pagmamaneho: A1=DC12V Condensing fan A2=DC24V Condensing fan A3=AC380V A4=AC440V High-efficiency na motor A5=Hydraulic Motor | Bypass Valve: M=Walang Bypass Valve⬅Standard W=Palabas | Direksyon ng hangin: X=Suction⬅Standard C=Blowing | Temp.Controller: O=Walang controller⬅Standard T=Temp.Mga Switch--Action Temp.: T50=50℃,T60=60℃,T70=70℃ C=Temp.Transmitter-- C1=Compact,C2=Digital Z=Nakasama sa switch ng pangkontrol na temperatura ng proteksyon.(Available lang kapag ang drive mode ay condensing fan) | Proteksyon ng Heatsink: O=Walang proteksyon⬅Standard S=Anti-Bato lambat |
1. Ang diameter ng piping ay dapat itugma sa laki ng oil inlet at outlet.Maaari itong maging mas maliit sa parehong oras, ngunit hindi maaaring mas malaki sa parehong oras.Gumamit ng mga hose na may mataas na presyon at direktang mga ulo hangga't maaari upang mabawasan ang resistensya sa pagbabalik ng langis.
2. Kapag ginagamit ang oil return cooling method, dapat na mag-install ng bypass unloading circuit, at ang opening pressure ng back pressure valve ay mas mababa sa 0.5MPa upang maiwasang masira ang radiator ng labis na pulse pressure kapag sinimulan ang system.
3. Ang lokasyon ng air cooler ay dapat na maiwasan ang panginginig ng boses at pagsuntok, at ang air intake at tambutso ay dapat na libre at walang harang, at ang pag-install ay dapat na matatag.
4. Hindi inirerekomenda na mag-install ng filter sa outlet ng langis.