DXD Series DC Condensing Fan Air Cooler

Short Description:

The air cooler is a kind of heat exchanger, which is characterized by using air as the cooling medium, and using the heat of the internal medium of the fan to forcibly take away. Because it is often used for cooling hydraulic oil, it is also often called an air-cooled oil cooler.

Aluminum alloy high-density heat sink, precision manufacturing, quality assurance. Thickened mounting feet, safe and reliable quality, more durable. Equipped with two or four fans, more air volume and better cooling effect

Stable performance fan, overall anti-leakage design, beautiful and durable, better heat dissipation


Product Detail

Product Tags

Features

Quality Assurance, Easy Installation, One Year Warranty
Through the vacuum brazing process, the cooler is driven by an integrated axial fan, which can run for a long time and achieve stable cooling effect.
· The temperature controller can be installed.
· Various forms of pressure protection are available.
· The oil inlet and outlet of the cooler are standard G thread, and SAE flanges can also be customized or connected according to requirements.

Spcification

Model DXD-2 DXD-3 DXD-4 DXD-5 DXD-6 DXD-7 DXD-8 DXD-9 DXD-10
Cooling Capacity*
(kW)
8 13 18 22 30 40 45 55 65
Rated Flow
(L/min)
80 100 150 200 250 300 350 400 500
Max.Working Pressure
(bar)
20 20 20 20 20 20 20 20 20
Fan Power
(W)
150 200 200 2*150 2*150 2*150 2*200 4*200 4*200
Working Voltage                      (V) 24 24 24 24 24 24 24 24 24
Inlet&Outlet Thread   G1¾''   G1 ''   G1¼''   G1¼''   G1¼''   G1¼''  G1½''  G1½''  G1½''
Thermometric Thread  G3/8''  G3/8''  G3/8''  G3/8''  G3/8''  G3/8''  G3/8''  G3/8''  G3/8''
Noise Level**                 (dB) 52 68 71 72 74 75 78 79 84
A
(mm±5)
365 425 530 585 630 630 750 835 970
B
(mm±5)
400 500 565 600 625 625 765 920 1060
C
(mm±2)
250 250 260 300 300 330 400 400 400
D
(mm±2)
230 290 390 450 490 490 560 645 700
E
(mm±2)
210 210 220 260 260 280 350 350 350
F
(mm±5)
295 384 434 475 495 495 634 780 920
G
(mm±5)
45 50 55 55 55 55 55 60 60
K
(mm±10)
240 280 310 330 330 350 390 465 380
L
(mm±2)
40 40 40 40 45 45 45 50 50
M
(mm±2)
12*18 12*18 12*18 12*18 14*22 14*22 14*22 14*22 14*22
W1 180 200 250 300 300 300 350 400 450
W2 360 400 500 600 600 700 800 900 1000
Note:   * Cooling capacity: cooling power at △T=40℃.
** The noise value is measured at a distance of 1m from the cooler, which is only for reference.
Because it is affected by the surrounding environment, medium viscosity and reflection.
*** This table only takes AC380V-50HZ as an example.
**** Motor power protection level: IP44; Insulation class: F; CE standard.
(Other options please contact DONGXU)

Dimensions

DXD Specification (1)
DXD Specification (2)

Application

Hydraulic system circuit, independent cooling circuit and lubricating oil cooling system.
For examples, walking machinery, machine tool machinery, agricultural machinery, engineering vehicles, construction machinery, and so on.

1walking machine

Walking machine

2Machine tools

Machine tools

3Agriculture

Agriculture

4Engineering

Engineering

6Construction

Construction

Description Of Model Label

DXD 8 A2 N C X O O
Cooler Type:
Integral DC Condenser Fan Series
Plate Size:
2/3/4/5/6/7/8/9/10
Voltage:
A2=DC24V⬅Standard
A1=DC12V
Bypass Valve:
N=Build-in⬅Standard
W=External
M=Without Bypass Valve
Oil Hole Direction:
C=Side in side out⬅Standard
S=Up in up out
Wind Direction:
X=Suction⬅Standard
C=Blowing
Temp. Controller:
O=Without controller⬅Standard
Z=Integrated self-protected temperature control switch
C=Temp. Transmitter--
    C1=Compact,C2=Digital
Heatsink Protection:
O=Without protection⬅Standard
S=Anti-Stone net
C=Dust net

Installation & Maintenance

1. The cooler must be placed in a well-ventilated place, and it is easy to deal with the dirt on the air inlet side. There must be a space (above the radius of the wind blade) before and after to facilitate air circulation and good heat exchange effect.
2. In order to protect the cooler from rupture, when the cooler is installed in the oil return circuit, a bypass unloading circuit must be installed in parallel with the cooler, and when the pressure relief encounters a convex wave, it can be opened and unloaded preferentially.
3. For correct installation, it is recommended to use a hose, properly install a bypass unloading circuit, or use an independent circulating cooling method.
4. For the cleaning of the air side, compressed air or hot water can be used to remove it along the direction of the aluminum sheet. Please pay attention to the power off during cleaning, and protect the fan coil from entering water.


  • Previous:
  • Next: