DXT Serie Multi-funktionell Effektiv Air Cooler
De Kühler, duerch Vakuum-Lotprozess, ass stabilen Drock, dee mat verschiddenen Motorarten ausgestatt ka ginn a wäit a ville Beräicher gëllen.
· Temperaturkontroller ka gewielt ginn.
· Eng Vielfalt vun Drockschutzformen kënnen ausgewielt ginn.
DXT Serie High Effizienz Motor ugedriwwen Air Coolers
Modell | A | B | C | D | E | G | H | K | L | M | X | F | W1 | W2 |
DXT-2-A3 | 352 | 415 | 250 | 150 | 200 | 115 | 20 | 470 | 25 | Φ14 | G1" | 345 | 150 | 300 |
DXT-3-A3 | 456 | 540 | 300 | 200 | 250 | 160 | 20 | 500 | 25 | Φ14 | G1" | 460 | 200 | 400 |
DXT-4-A3 | 450 | 560 | 300 | 200 | 250 | 160 | 20 | 552 | 30 | Φ14 | G1¼" | 469 | 220 | 450 |
DXT-5-A3 | 470 | 710 | 300 | 200 | 250 | 165 | 20 | 559 | 30 | Φ14 | G1¼" | 620 | 220 | 450 |
DXT-6-A3 | 617 | 810 | 400 | 310 | 350 | 235 | 20 | 613 | 50 | Φ16 | G1¼" | 720 | 280 | 550 |
DXT-7-A3 | 617 | 960 | 400 | 310 | 350 | 235 | 20 | 660 | 50 | Φ16 | G1¼" | 870 | 280 | 550 |
DXT-8-A3 | 710 | 980 | 450 | 400 | 400 | 280 | 20 | 748 | 50 | Φ16 | G1½" | 880 | 500 | 1000 |
DXT-9-A3 | 990 | 1350 | 580 | 440 | 215 | 780 | 40 | 730 | 63 | Φ16 | Flange | 1182 | 550 | 1200 |
DXT-10-A3 | 990 | 1350 | 580 | 440 | 215 | 780 | 40 | 780 | 63 | Φ16 | Flange | 1172 | 620 | 1200 |
DXT-11-A3 | 1276 | 1570 | 750 | 525 | 210 | 1064 | 48 | 920 | 100 | Φ16 | Flange | 1332 | 800 | 1600 |
DXT Serie hydraulesch Motor ugedriwwen Air Coolers
Modell | A | B | C | D | E | G | H | L | M | X | F | W1 | W2 |
DXT-2-A5 | 352 | 415 | 250 | 150 | 200 | 115 | 20 | 25 | Φ14 | G1" | 345 | 150 | 300 |
DXT-3-A5 | 456 | 540 | 300 | 200 | 250 | 160 | 20 | 25 | Φ14 | G1¼" | 460 | 200 | 400 |
DXT-4-A5 | 450 | 560 | 300 | 200 | 250 | 160 | 20 | 30 | Φ14 | G1¼" | 469 | 220 | 450 |
DXT-5-A5 | 470 | 710 | 300 | 200 | 250 | 165 | 20 | 30 | Φ14 | G1¼" | 620 | 220 | 450 |
DXT-6-A5 | 617 | 810 | 400 | 310 | 350 | 235 | 20 | 50 | Φ16 | G1¼" | 720 | 280 | 550 |
DXT-7-A5 | 617 | 960 | 400 | 310 | 350 | 235 | 20 | 50 | Φ16 | G1¼" | 870 | 280 | 550 |
DXT-8-A5 | 710 | 980 | 450 | 400 | 400 | 280 | 20 | 50 | Φ16 | G1½" | 880 | 500 | 1000 |
DXT-9-A5 | 990 | 1350 | 580 | 440 | 215 | 780 | 40 | 63 | Φ16 | Flange | 1182 | 550 | 1200 |
DXT-10-A5 | 990 | 1350 | 580 | 440 | 215 | 780 | 40 | 63 | Φ16 | Flange | 1172 | 620 | 1200 |
DXT-11-A5 | 1276 | 1570 | 750 | 525 | 210 | 1064 | 48 | 100 | Φ16 | Flange | 1332 | 800 | 1600 |
DXT Serie DC Kondensator Fan Typ Air Cooler
Modell | A | B | C | D | E | G | H | L | M | X | F | W1 | W2 |
DXT-1-A2 | 270 | 335 | 200 | 80 | 150 | 65 | 15 | 25 | Φ14 | G1" | 270 | 100 | 250 |
DXT-2-A2 | 352 | 415 | 250 | 150 | 200 | 115 | 20 | 25 | Φ14 | G1" | 345 | 150 | 300 |
DXT-3-A2 | 456 | 540 | 300 | 200 | 250 | 160 | 20 | 25 | Φ14 | G1" | 460 | 200 | 400 |
DXT-4-A2 | 450 | 560 | 300 | 200 | 250 | 160 | 20 | 30 | Φ14 | G1¼" | 469 | 220 | 450 |
DXT-5-A2 | 470 | 710 | 300 | 200 | 250 | 165 | 20 | 30 | Φ14 | G1¼" | 620 | 220 | 450 |
DXT-6-A2 | 617 | 810 | 400 | 310 | 350 | 235 | 20 | 50 | Φ16 | G1¼" | 720 | 280 | 550 |
DXT Serie Iwwergräifend Parameter Dësch
Modell | Motor Volt (V) | Motor Muecht (KW) | Blade Speed (r/min) | Kaméidi Niveau (dB) | Cooling Kapazitéit (KW) | Max.Aarbechtsdrock (bar) | Max.Temp. (℃) | Max.Flow (l/min) |
DXT-1 | 12 | 0.12 | 2700 | 70 | 5.5 | 20 | 130 | 60 |
24 | 0.15 | |||||||
DXT-2 | 12 | 0.12 | 2700 | 75 | 10 | 20 | 130 | 100 |
24 | 0.15 | 73 | ||||||
220/380 | 0,25 | 1450 | 78 | |||||
Hydraulesch Motor 10 ccm | / | 2800 | 77 | |||||
DXT-3 | 12 | 0.2 | 2700 | 76 | 16 | 20 | 130 | 150 |
24 | 0.2 | 78 | ||||||
220/380 | 0,37 | 1450 | 79 | |||||
Hydraulesch Motor 10 ccm | / | 2800 | 78 | |||||
DXT-4 | 12 | 0.2 | 2700 | 77 | 19 | 20 | 130 | 200 |
24 | 0.2 | 78 | ||||||
220/380 | 0,37 | 1450 | 79 | |||||
Hydraulesch Motor 10 ccm | / | 2800 | ||||||
DXT-5 | 12 | 0.2 | 2700 | 79 | 28 | 20 | 130 | 250 |
24 | 0.2 | |||||||
220/380 | 0,75 | 1450 | 82 | |||||
Hydraulesch Motor 10 ccm | / | 1500 | 80 | |||||
DXT-6 | 220/380 | 1.5 | 1450 | 87 | 35 | 20 | 130 | 300 |
Hydraulesch Motor 16 ccm | / | 1500 | 84 | |||||
DXT-7 | 220/380 | 1.5 | 1450 | 87 | 55 | 20 | 130 | 350 |
Hydraulesch Motor 16 ccm | / | 1500 | 84 | |||||
DXT-8 | 220/381 | 2.2 | 1450 | 89 | 70 | 20 | 130 | 400 |
Hydraulesch Motor 16 ccm | / | 1500 | 85 | |||||
DXT-9 | 220/381 | 4 | 1450 | 96 | 110 | 20 | 130 | 450 |
Hydraulesch Motor 25 ccm | / | 1500 | 87 | |||||
DXT-10 | 220/382 | 7.5 | 1450 | 102 | 140 | 20 | 130 | 500 |
Hydraulesch Motor 25 ccm | / | 1500 | 92 | |||||
DXT-11 | 220/382 | 11 | 1450 | 106 | 245 | 20 | 130 | 600 |
Hydraulesch Motor 32 ccm | / | 1500 | 97 |
Hydraulesch System Circuit, onofhängege Kühlschaltung a Schmierölkühlsystem.
Zum Beispill, Maschinn Handwierksgeschir, Biergbau Maschinnen, hydraulesch Maschinnen, Kraaftstatioun, Wandkraaft Ausrüstung, a sou weider.
Bau Maschinnen
Ingenieur Maschinnen
Hydraulesch Maschinnen
Biergbau Maschinnen
Spadséier- Maschinnen
DXT | 8 | A3 | M | X | O | O |
Cooler Typ: Multi-funktionell Effektiv Serie | Plack Gréisst: 1/2/3/4/5/6/7/8/9/10/11 | Fuert Wee: A1 = DC12V Kondensator Fan A2 = DC24V Kondensator Fan A3 = AC380V A4 = AC440V High-Effizienz Motor A5 = Hydraulesch Motor | Bypass Valve: M=Ouni Bypass Valve⬅Standard W = Extern | Wandrichtung: X=Saug⬅Standard C=Bléien | Temp.Controller: O = Ouni Controller⬅Standard T = Temp.Schalter - Aktioun Temp.: T50=50℃, T60=60℃, T70=70℃ C = Temp.Sender-- C1 = Kompakt, C2 = Digital Z = Integréiert mat engem Schutztemperaturkontrollschalter.(Nëmme verfügbar wann de Fuermodus e Kondensatiounsfan ass) | Heizkierper Schutz: O = Ouni Schutz⬅Standard S=Anti-Stone net |
1. Den Duerchmiesser vun der Päif soll mat der Gréisst vun der Ueleg Inlet an Outlet ugepasst ginn.Et kann gläichzäiteg méi kleng sinn, awer kann net gläichzäiteg méi grouss sinn.Benotzen héich-Drock flexibelen Schlauch an direkt Kapp sou vill wéi méiglech Ueleg Retour Resistenz ze reduzéieren.
2. Wann Dir d'Ueleg Retour Killmethod benotzt, muss e Bypass Entluede Circuit installéiert ginn, an den Ouverturesdrock vum Réckdruckventil ass manner wéi 0,5MPa fir ze verhënneren datt de Heizkierper duerch exzessive Pulsdruck beschiedegt gëtt wann de System gestart gëtt.
3. D'Plaz vum Loftkühler sollt Schwéngungen a Punching vermeiden, an d'Loftaufnahme an d'Auspuff solle gratis an onobstruéiert sinn, an d'Installatioun soll fest sinn.
4. Et gëtt net empfohlen fir e Filter am Uelegausgang ze installéieren.